AQUANEXT SPLIT
Aquanext Split Inverter combines a heat pump and a hot water tank available in 150, 200 or 270 liters. It offers the best performance on the market and maximum installation flexibility (2-20 m, height difference +/- 10m).
Description
>PROFITS AND PERFORMANCE
Enamelled steel tank.
Double protection of the tank tank, provided by an active anode and a magnesium anode.
Double power level soapstone resistance, allowing maintenance without emptying the tank and limits scaling.
COP up to 3.55.
Quiet operation with 56 dB(A) of acoustic power.
Domestic Hot Water Class: A+
Parts warranty: 2 years
Tank warranty: 5 years
>SAVINGS AND COMFORT
80% energy savings compared to the consumption of a conventional electric water heater.
Up to 838 liters of domestic hot water available at 40°C (V40td in off-peak operation + 1 6-hour restart).
>BETTER PERFORMANCE
COP up to 3.55, the highest on the market.
Fast heating time, less than 6 hours.
Inverter technology: Modulates its power according to needs for water heating.
>INSTALLATION FLEXIBILITY
Refrigeration connections of 2 to 20 meters between the heat pump and the tank and a difference in height of +/-10 meters.
Wall or floor installation for perfect integration into all configurations.
TECHNICAL DATA
model | 150 | 200 | 270 | ||
---|---|---|---|---|---|
tank | |||||
Storage capacity Domestic hot water | lt | 150 | 200 | 270 | |
Type of installation | Vertical | Vertical | Stable | ||
Installation type | Wall | Wall | On the ground | ||
DHW comfort – volume of hot water at 40°C (Vmax) * | lt | 193 | 267 | 375 | |
Corrosion protection | Impressed current titanium anode + magnesium anode | ||||
Water connection | 3/4˝ M | ||||
Type and power of electric booster | W | Steatite 2,5kW (1kW + 1,5 kW) | |||
Indoor sound power level | dB(A) | 15 | |||
Dimensions (width, depth, height) | mm | 560 x 600 x 1150 | 560 x 600 x 1476 | 600 x 632 x 1665 | |
netweight | kg | 60 | 65 | 76 | |
Heat pump | |||||
Sound power level outside | dB(A) | 56 | |||
Operating range | °C | -10 à +42 | |||
Refrigerant type | R134a | ||||
Refrigerant charge | kg | 1,1 | |||
Type of refrigeration connection | 1/4‘’ – 3/8’’ | ||||
Length of the refrigeration connection (min/max) | m | 2/20 | |||
Max elevation (positive or negative) | m | 10 | |||
NF Electricity Certification Thermodynamic Performance | +++ <span | ||||
COP DHW at +7°C * | 3,33 | 3,26 | 3,55 | ||
Seasonal energy efficiency ηwh / ErP class ** | % / – | 134/ | 134 | 144 | |
Declared draw profiling | L XL | ||||
Heating time * | h:min | 3:19 | 4:34 | 05:38 | |
Supply voltage | V | 230 V – 50 Hz – 1 ph | |||
Average electrical power absorbed | W | 700 | |||
Maximum absorbed | A | 10.8 | |||
current Dimensions (width, depth, height) | mm | 832 x 337 x 556 | 832 x 337 x 556 | 832 x 337 x 556 | |
Net weight | kg | 32 |