ARIANEXT COMPACT M LINK R32
MONOBLOCK AIR/WATER HEAT PUMP.
Inverter monobloc heat pump with ecological R32
gas. For heating and cooling. Prepared for
combination with a domestic hot water tank.
The Arianext M Ext R32 outdoor unit is equipped with a
brushless motor for maximum operating silence and a twin
rotary compressor which ensures silent and efficient operation
even at partial loads and in harsh climates. Inverter control to
adapt the power supplied to that required by the system at any
time, minimizing on/off cycles and 1″ water connections.
Internal column unit with integrated boiler. Highly insulating coating, magnetic
filter and 12 lt expansion tank integrated as standard. Back up electrical resistors
with modular power (2+2) kW up to the 80 model, (2+2+2) kW for the 120 and
150 models. Expert HD interface as standard which can be integrated on the
machine. Boiler set up for domestic hot water recirculation. Integrable
accessories
Description
> HIGH PERFORMANCE
- Very high efficiency, even in harsh climates
- Maximum silence, up to 53 dB(A)
- Minimized domestic water heating times
- Power range from 1.7 to 17.7 kW
- Thanks to the DHW electric resistance (optional) it is possible to satisfy the heating and cooling needs at the same time
hot water
> EASY INSTALLATION
- Integrated magnetic filter as standard
- 12 lt expansion vessel integrated as standard
- 8 lt expansion vessel for sanitary fixture that can be integrated inside
- 15 lt buffer that can be integrated inside
- Simplified and unified connection kits for different types of installation
- Available in version with integrated double zone
> SMART CONNECTIVITY
- Built-in Wi-Fi
- Expert HD system interface as standard, which can be integrated on the product
- Remote control via ChaffoLink App
- Remote assistance service available as an option
- Voice control via Amazon Alexa and Google Assistant
> SIMPLIFIED MAINTENANCE
- Easy access front door
- Highly insulating coating that prevents condensation from forming
Technical Information
TECHNICAL DATA
MODEL | 35 M LINK R32 | 50 M LINK R32 | 80 M-T LINK R32 | 120 M-T LINK R32 | 150 M-T LINK R32 | |
---|---|---|---|---|---|---|
Heating performance* | ||||||
Nominal heat output(Ta +7°C, Tw 35°C) | kW | 3,5 | 5 | 8 | 12 | 15 |
COP nom (Ta +7°C, Tw 35°C) | 5,1 | 5 | 4,8 | 4,9 | 4,7 | |
Useful thermal power at full capacity(Pn**) (Ta +7°C, Tw 35°C) | kW | 5,9 | 6,7 | 8,7 | 12 | 15 |
COP to Pn**(Ta +7°C, Tw 35°C) | 4,6 | 4,5 | 4,6 | 4,8 | 4,7 | |
Thermal power (Ta -7°C, Tw 35°C) | kW | 3,5 | 5,0 | 7,4 | 9,5 | 11,0 |
COP nom (Ta -7°C, Tw 35°C) | 3,1 | 2,9 | 3,0 | 3,2 | 3,1 | |
Cooling performance** | ||||||
Thermal power (Ta 35°C, Tw 18°C) | kW | 4,1 | 4,6 | 7 | 10,7 | 12,5 |
EER nom (Ta 35°C, Tw 18°C) | 5,3 | 4,6 | 4,7 | 5,1 | 4,7 | |
Thermal power (Ta 35°C, Tw 7°C) | kW | 3,5 | 5 | 7 | 9,1 | 11 |
EER (Ta 35°C, Tw 7°C) | 3,4 | 2,9 | 3,1 | 3,2 | 2,9 | |
Performance in domestic hot water*** | ||||||
Load profile | L | L | L | L | L | |
Nominal storage volume | lt | 180 | 180 | 180 | 180 | 180 |
Warm-up time | h:min | 1:55 | 1:31 | 1:03 | 0:55 | 0:50 |
Stand-by power input (Pes) | W | 38 | 38 | 38 | 38 | 38 |
COP in domestic hot water (35°C) | 3,10 | 3,10 | 3,10 | 3,10 | 3,10 | |
Maximum quantity at unloading(Vmax) | lt | 233 | 233 | 233 | 233 | 233 |
Data ERP | ||||||
Energy class in heating 35°C /55 °C | A+++/A++ | A+++/A++ | A+++/A++ | A+++/A++ | A+++/A+++ | |
Energy class in domestic hot water | A+ | A+ | A+ | A+ | A+ |
TECHNICAL FUTURES
ARIANEXT | 35 M EXT | 50 M EXT | 80 M-T EXT | 120 M-T EXT | 150 M-T EXT | |
---|---|---|---|---|---|---|
HEATING (heat pump performance) | ||||||
T flow min/max | °C | -20/35 | ||||
T air min/max | °C | 20/60 | ||||
T air +7°C, T water 35/30°C | Min / Nom / Max | Min / Nom / Max | Min / Nom / Max | Min / Nom / Max | Min / Nom / Max | |
Thermal power | kW | 1,68/3,50/6,35 | 1,68/5,00/7,57 | 2,74/8,00/11,74 | 4,08/12,00/14,37 | 4,08/15,00/17,65 |
Nominal absorbed power | kW | 0,69 | 1,00 | 1,67 | 2,45 | 3,19 |
COP nom | 5,10 | 5,00 | 4,80 | 4,90 | 4,70 | |
T air -7°C, T water 35/30°C | Min / Nom / Max | Min / Nom / Max | Min / Nom / Max | Min / Nom / Max | Min / Nom / Max | |
Thermal power | kW | 1,04/3,51/4,52 | 1,04/5,00/5,20 | 1,79/7,41/8,45 | 2,99/9,51/11,47 | 2,99/11,00/13,79 |
Nominal absorbed power | kW | 1,13 | 1,72 | 2,47 | 2,97 | 3,55 |
COP nom | 3,1 | 2,90 | 3,00 | 3,20 | 3,10 | |
T air +7°C, T water 45/40°C | Min / Nom / Max | Min / Nom / Max | Min / Nom / Max | Min / Nom / Max | Min / Nom / Max | |
Thermal power | kW | 1,60/3,00/6,04 | 1,60/4,05/7,19 | 2,61/6,00/11,50 | 4,02/8,20/13,65 | 3,88/9,90/16,77 |
Nominal absorbed power | kW | 0,8 | 1,11 | 1,62 | 2,00 | 2,48 |
COP nom | 3,74 | 3,65 | 3,70 | 4,10 | 4,00 | |
COOLING (heat pump performance) | ||||||
T flow min/max | °C | 10/43 | ||||
T air min/max | °C | 5/23 | ||||
T air 35°C, T water7/12°C | Min / Nom / Max | Min / Nom / Max | Min / Nom / Max | Min / Nom / Max | Min / Nom / Max | |
Thermal power | kW | 1,65/3,50/3,81 | 1,67/5,00/5,40 | 2,65/7,00/8,50 | 3,70/9,05/10,30 | 3,70/11,00/11,88 |
Nominal absorbed power | kW | 1,03 | 1,75 | 2,26 | 2,87 | 3,75 |
EER nom | 3,40 | 2,85 | 3,10 | 3,15 | 2,93 | |
T air 35°C, T water 18/23°C | Min / Nom / Max | Min / Nom / Max | Min / Nom / Max | Min / Nom / Max | Min / Nom / Max | |
Thermal power | kW | 2,39/4,08/6,59 | 2,38/4,63/8,56 | 3,45/7,00/12,65 | 4,78/10,74/13,30 | 4,78/12,50/17,20 |
Nominal absorbed power | kW | 0,77 | 1,02 | 1,49 | 2,11 | 2,66 |
EER nom | 5,29 | 4,56 | 4,70 | 5,08 | 4,70 | |
ErP data (medium climate, low flow temperature) | ||||||
External unit sound power | dB(A) | 53 | 55 | 57 | 58 | 58 |
Annual energy absorbed | kWh/year | 2790 | 3360 | 4405 | 5335 | 6217 |
Seasonal yield | % | 134 | 136 | 140 | 143 | 151 |
ARIANEXT OUTDOOR UNIT | ||||||
Weight | kg | 66 | 66 | 104 | 131 | 131 |
Refrigerant type | R32 | |||||
Refrigerant charge | g | 1000 | 1000 | 1400 | 2100 | 2100 |
GWP | 675 | |||||
CO2 equivalent | t | 0,68 | 0,68 | 0,95 | 1,42 | 1,42 |
Inlet – outlet pipe connection | Inches | 1”M | ||||
Voltage/phases/frequency | v/ph/Hz | 230-1-50 | 230-1-50 | 400-3-50 | 400-3-50 | 400-3-50 |
Maximum power absorbed* | kW | 2,54 | 3,06 | 4,98 | 5,00 | 6,18 |
Compressor type | DC TWIN-ROTARY | |||||
Degree of electrical protection | IP24 | |||||
Minimum water content in the primary of the system | 17,50 | 25,00 | 40,00 | 60,00 | 75,00 |